An instrumented glove for monitoring hand function
Published in American Institute of Physics Inc.
2018
PMID: 30399736
Volume: 89
   
Issue: 10
Abstract
The measurement of hand kinematics is important for the assessment and rehabilitation of the paralysed hand. The traditional method of hand function assessment uses a mechanical or electronic goniometer placed across the joint of interest to measure the range of joint movement. Mechanical goniometers are imprecise and lack the ability to provide a dynamic measurement; electronic goniometers are expensive and cumbersome to use during therapy. An alternative to the goniometric based assessment is to use inertial motion sensors to monitor the hand movement - these can be incorporated in a glove. In this paper, we present the design of an instrumented glove equipped with Magnetic, Angular Rate and Gravity (MARG) sensors for the objective evaluation of hand function. The instrumented glove presented in this paper is designed to assess the range of movement of the hand and also monitor the hand function during the course of hand rehabilitation. Static and dynamic calibrations were performed for the Euler angles calculated from the MARG sensors. The results are also presented for physiological flexion/extension of the wrist (relative roll), flexion/extension of elbow (relative pitch), and internal rotation/external rotation (relative yaw). The static calibration results gave mean absolute errors of 4.1° for roll, 4.0° for pitch, and 4.6° for yaw. From the dynamic calibration, the speed of response to a step change gave a convergence time of 0.4 s; sinusoidally oscillating movement gave good tracking at 0.2 Hz but exhibits overshoot errors at higher frequencies which were tested to be 1 Hz. We present the results of the calibration of the instrumented glove (one sensor pair measuring one joint angle) measuring anatomical joint angles - mean absolute errors during static calibration: 6.3° for a relative roll (wrist flexion/extension), 5.0° for relative pitch (elbow flexion/extension), and 4.5° for relative yaw (shoulder internal rotation/external rotation). The experimental results from the instrumented glove are promising, and it can be used as an alternative to the traditional goniometer based hand function assessments. © 2018 Author(s).
About the journal
JournalData powered by TypesetReview of Scientific Instruments
PublisherData powered by TypesetAmerican Institute of Physics Inc.
ISSN00346748
Open AccessNo
Concepts (33)
  •  related image
    Calibration
  •  related image
    Errors
  •  related image
    GONIOMETERS
  •  related image
    Dynamic calibration
  •  related image
    Dynamic measurement
  •  related image
    ELBOW FLEXION/EXTENSION
  •  related image
    HAND REHABILITATION
  •  related image
    MAGNETIC , ANGULAR RATE AND GRAVITY SENSORS
  •  related image
    Mean absolute error
  •  related image
    Objective evaluation
  •  related image
    RANGE OF JOINT MOVEMENT
  •  related image
    Rotation
  •  related image
    Accelerometry
  •  related image
    Biomechanics
  •  related image
    Devices
  •  related image
    Electronic device
  •  related image
    HAND
  •  related image
    Human
  •  related image
    JOINT CHARACTERISTICS AND FUNCTIONS
  •  related image
    Magnetism
  •  related image
    Movement (physiology)
  •  related image
    Pathophysiology
  •  related image
    PHYSIOLOGIC MONITORING
  •  related image
    Physiology
  •  related image
    Tremor
  •  related image
    Biomechanical phenomena
  •  related image
    HAND
  •  related image
    Humans
  •  related image
    Magnetic phenomena
  •  related image
    MONITORING, PHYSIOLOGIC
  •  related image
    Movement
  •  related image
    RANGE OF MOTION, ARTICULAR
  •  related image
    WEARABLE ELECTRONIC DEVICES