Towards reduction of SAR in scaling up in vivo pulsed EPR imaging to larger objects
Sankaran Subramanian
Published in Academic Press Inc.
2019
PMID: 30579225
Volume: 299
   
Pages: 42 - 48
Abstract
An excessive RF power requirement is one of the main obstacles in the clinical translation of EPR imaging. The radio frequency (RF) pulses used in EPR imaging to excite electron spins must be very short to match their fast relaxation. With traditional pulse schemes and ninety degree flip angles, this can lead to either unsafe specific absorption rate (SAR) levels or unfeasibly long repetition times. In spectroscopy experiments, it has been shown that stochastic excitation and correlation detection can reduce the power while maintaining sensitivity but have yet to be applied to imaging experiments. Stochastic excitation is implemented using a pseudo-random phase modulation of the input stimulus. Using a crossed coil resonator assembly comprised of an outer saddle coil and an inner surface coil, it was possible to obtain a minimum isolation of ∼50 dB across a 12 MHz bandwidth. An incident peak RF power of 5 mW was used to excite the system. The low background signal obtained from this resonator allowed us to generate images with 32 dB (>1000:1) signal-to-noise ratio (SNR) while exciting with a traditional pulse sequence in a phantom containing the solid paramagnetic probe NMP-TCNQ (N-methyl pyridinium tetracyanoquinodimethane). Using two different stochastic excitation schemes, we were able to achieve a greater than 4-fold increase in SNR at the same peak power and number of averages, compared to single pulse excitation. This procedure allowed imaging at significantly lower RF power levels than used in conventional EPR imaging system configurations. Similar techniques may enable clinical applications for EPR imaging by facilitating the use of larger RF coils while maintaining a safe SAR level. © 2018
About the journal
JournalJournal of Magnetic Resonance
PublisherAcademic Press Inc.
ISSN10907807
Open AccessYes
Concepts (17)
  •  related image
    Correlation methods
  •  related image
    Digital signal processing
  •  related image
    Imaging systems
  •  related image
    Paramagnetic resonance
  •  related image
    Pulse repetition rate
  •  related image
    Resonators
  •  related image
    Signal to noise ratio
  •  related image
    Stochastic systems
  •  related image
    BAND-PASS SAMPLING
  •  related image
    CORRELATION DETECTION
  •  related image
    RADIO FREQUENCY PULSE
  •  related image
    SINGLE-PULSE EXCITATIONS
  •  related image
    Specific absorption rate
  •  related image
    STOCHASTIC EXCITATIONS
  •  related image
    System configurations
  •  related image
    TETRACYANOQUINODIMETHANE
  •  related image
    Radar imaging