Header menu link for other important links
X
Role of discrete heating on the efficient thermal management within porous square and triangular enclosures via heatline approach
Published in Elsevier Ltd
2017
Volume: 112
   
Pages: 489 - 508
Abstract
The conventional method of differential heating within an enclosure may result in the inadequate thermal mixing and that may further lead to the poor thermal management. In order to enhance the overall thermal mixing, the discrete heating strategy may be considered as an effective alternative. In the current work, natural convection studies have been carried out within discretely heated porous square and triangular (type 1 and type 2) enclosures during natural convection. Overall, five different discrete heating strategies (cases 1–4: symmetric heating, case 5: asymmetric heating) have been considered for the present work. The heatline method has been implemented to visualize the heat flow pattern within the cavities for a wide range of parameters (Prm=0.015–7.2,Dam=10-5–10-2,Ram=106). In order to solve the governing equations and Poisson equations for streamfunction and heatfunction, the Galerkin finite element method has been used. At Dam=10-4, computational results clearly indicate the onset of convection whereas enhanced convection is found to occur at Dam=10-2 based on the presence of intense fluid and heatline cells. The intensity of heat flow is observed to be higher for the asymmetric distributed heating strategy compared to the symmetric distributed heating configurations. Heatlines depict the role of hot regime along the side walls and they are also useful in explaining the variations of the local and average Nusselt numbers for the various cases. Common to all the cases, the average heat transfer rate within the triangular- type 1 enclosure is higher compared to the square and triangular-type 2 enclosures irrespective of Dam and Prm. The extent of the thermal mixing in each case has been quantified using the cup-mixing temperature which has been evaluated at higher and lower Dam in order to establish the effect of porosity. It is concluded that the thermal mixing is more effective within the square and triangular-type 2 enclosures at both Dam=10-4 and 10-2. The cases 2 and 5 were inferred to be the optimal discrete heating strategies. © 2017 Elsevier Ltd
About the journal
JournalData powered by TypesetInternational Journal of Heat and Mass Transfer
PublisherData powered by TypesetElsevier Ltd
ISSN00179310
Open AccessNo
Concepts (18)
  •  related image
    Enclosures
  •  related image
    Finite element method
  •  related image
    Flow patterns
  •  related image
    Heat transfer
  •  related image
    Mixing
  •  related image
    Natural convection
  •  related image
    Porous materials
  •  related image
    Temperature control
  •  related image
    THERMAL VARIABLES CONTROL
  •  related image
    Average heat transfers
  •  related image
    Computational results
  •  related image
    Conventional methods
  •  related image
    DIFFERENTIAL HEATING
  •  related image
    DISCRETE HEATING
  •  related image
    GALERKIN FINITE ELEMENT METHODS
  •  related image
    Heatline
  •  related image
    TRIANGULAR ENCLOSURE
  •  related image
    Heating