Header menu link for other important links
X
On non-invasive measurement of gastric motility from finger photoplethysmographic signal
Published in
2010
PMID: 20614246
Volume: 38
   
Issue: 12
Pages: 3744 - 3755
Abstract
This article investigates the possibility of extracting gastric motility (GM) information from finger photoplethysmographic (PPG) signals non-invasively. Now-a-days measuring GM is a challenging task because of invasive and complicated clinical procedures involved. It is well-known that the PPG signal acquired from finger consists of information related to heart rate and respiratory rate. This thread is taken further and effort has been put here to find whether it is possible to extract GM information from finger PPG in an easier way and without discomfort to the patients. Finger PPG and GM (measured using Electrogastrogram, EGG) signals were acquired simultaneously at the rate of 100 Hz from eight healthy subjects for 30 min duration in fasting and postprandial states. In this study, we process the finger PPG signal and extract a slow wave that is analogous to actual EGG signal. To this end, we chose two advanced signal processing approaches: first, we perform discrete wavelet transform (DWT) to separate the different components, since PPG and EGG signals are non-stationary in nature. Second, in the frequency domain, we perform cross-spectral and coherence analysis using autoregressive (AR) spectral estimation method in order to compare the spectral details of recorded PPG and EGG signals. In DWT, a lower frequency oscillation (≈0.05 Hz) called slow wave was extracted from PPG signal which looks similar to the slow wave of GM in both shape and frequency in the range (0-0.1953) Hz. Comparison of these two slow wave signals was done by normalized cross-correlation technique. Cross-correlation values are found to be high (range 0.68-0.82, SD 0.12, R = 1.0 indicates exact agreement, p<0.05) for all subjects and there is no significant difference in cross-correlation between fasting and postprandial states. The coherence analysis results demonstrate that a moderate coherence (range 0.5-0.7, SD 0.13, p<0.05) exists between EGG and PPG signal in the ''slow wave'' frequency band, without any significant change in the level of coherence in postprandial state. These results indicate that finger PPG signal contains GM-related information. The findings are sufficiently encouraging to motivate further exploration of finger PPG as a non-invasive source of GM-related information. © 2010 Biomedical Engineering Society.
About the journal
JournalAnnals of Biomedical Engineering
ISSN00906964
Open AccessNo
Concepts (46)
  •  related image
    AR SPECTRAL ESTIMATION
  •  related image
    Cross correlations
  •  related image
    DISCRETE WAVELETS
  •  related image
    ELECTROGASTROGRAPHY
  •  related image
    GASTRIC MYOELECTRIC ACTIVITY
  •  related image
    MAGNITUDE SQUARED COHERENCES
  •  related image
    Nervous system
  •  related image
    Slow wave
  •  related image
    Correlation methods
  •  related image
    Discrete wavelet transforms
  •  related image
    Electrophysiology
  •  related image
    Estimation
  •  related image
    Frequency bands
  •  related image
    Frequency domain analysis
  •  related image
    Frequency estimation
  •  related image
    Spectrum analysis
  •  related image
    Signal processing
  •  related image
    Adult
  •  related image
    Article
  •  related image
    Biological model
  •  related image
    Biomedical engineering
  •  related image
    BREATHING RATE
  •  related image
    DIET RESTRICTION
  •  related image
    Electromyography
  •  related image
    Finger
  •  related image
    GASTROINTESTINAL MOTILITY
  •  related image
    Heart rate
  •  related image
    Human
  •  related image
    INTESTINE INNERVATION
  •  related image
    Male
  •  related image
    Methodology
  •  related image
    PHOTOELECTRIC PLETHYSMOGRAPHY
  •  related image
    Physiology
  •  related image
    POSTPRANDIAL STATE
  •  related image
    Statistics
  •  related image
    Wavelet analysis
  •  related image
    ENTERIC NERVOUS SYSTEM
  •  related image
    FASTING
  •  related image
    Fingers
  •  related image
    GASTROINTESTINAL MOTILITY
  •  related image
    Humans
  •  related image
    Models, biological
  •  related image
    PHOTOPLETHYSMOGRAPHY
  •  related image
    POSTPRANDIAL PERIOD
  •  related image
    RESPIRATORY RATE
  •  related image
    Young adult