Header menu link for other important links
X
Enhancing image quality of photoacoustic tomography using sub-pitch array translation approach: Simulation and experimental validation
Published in IEEE Computer Society
2019
PMID: 30932824
Volume: 66
   
Issue: 12
Pages: 3543 - 3552
Abstract
Objective: The purpose of this paper is to present a more convenient and practical alternate way of increasing the lateral discrete array sampling while using a typical λ pitch linear array transducer at receive for photoacoustic tomography (PAT) application. Methods: We have employed a linear translation-based approach, in which the array transducer is translated by sub-pitch amount to create an augmented RF frame data having denser lateral spatial sampling. The denser λ/2 and λ/4 pitch data were reconstructed and compared against conventional λ pitch reconstructed PAT image using simulation and tissue mimicking phantom experiments in terms of improvements in resolution and contrast. Results: The results from experiments demonstrate a 34.48% improvement in lateral resolution (LR), measured in terms of full-width at half-maximum of the lateral profile of point spread function, and a maximum of 7-dB improvement in contrast is achieved while using a λ/2-pitch configuration when compared to the conventional λ-pitch configuration. Conclusion: It was demonstrated that λ/2-and λ/4-pitch configurations result in better LR and contrast than λ-pitch configuration. Significance: Based on the results obtained, the proposed method has the potential to serve as an easy-To-integrate and simple way of achieving better image quality without requiring to increase the system complexity with existing transducer array probe technology in regular clinical scanners. © 1964-2012 IEEE.
About the journal
JournalData powered by TypesetIEEE Transactions on Biomedical Engineering
PublisherData powered by TypesetIEEE Computer Society
ISSN00189294
Open AccessNo
Concepts (16)
  •  related image
    Image quality
  •  related image
    Optical transfer function
  •  related image
    Photoacoustic effect
  •  related image
    Tomography
  •  related image
    Transducers
  •  related image
    Translation (languages)
  •  related image
    Wavelength
  •  related image
    Experimental validations
  •  related image
    LATERAL RESOLUTION
  •  related image
    LINEAR ARRAY TRANSDUCERS
  •  related image
    Linear arrays
  •  related image
    LINEAR TRANSLATION
  •  related image
    PHOTOACOUSTIC TOMOGRAPHY
  •  related image
    Pitch
  •  related image
    TISSUE MIMICKING PHANTOM
  •  related image
    Image enhancement