Thermo-mechanical response of hybrid polymer composites during tensile loading
, Monalisha Maharana
Published in American Society of Mechanical Engineers (ASME)
2017
Volume: 14
   
Abstract
The fiber reinforced polymers are candidate materials for critical applications in view of the high strength, stiffness characteristics; however, they are highly anisotropic and have complex failure mechanisms. Thermo-mechanical response characterization is one of the means of identifying damage progression in these materials. In this study, tensile tests were conducted on the hybrid composite laminates and Infrared thermographs were used to capture the thermal response of the specimen for the entire range of loading till failure. The tests were conducted on natural fiber composite specimens and hybrid (natural + synthetic fiber) composite specimens. The natural fibers used were in the form of uni-directionally stitched mats of Sunhemp, Kenaf and Flax fiber. The synthetic fibers used were bi-directionally woven Carbon fiber mat and Glass fiber mat. All the laminates were prepared using the hand lay-up technique. Four different configurations of the laminates were prepared. The natural fiber composite laminate comprised of Sunhemp fiber mat in a polyester resin system. The Sunhemp fiber mat was also used with woven Glass fiber mat on one side to prepare an unsymmetrical hybrid laminate. The Kenaf fiber mat was placed between layers of woven Glass fiber mats whereas the flax fiber mat was placed between the woven carbon fiber mats; Epoxy LY 556 and hardener Araldite® was used as the matrix. The finished laminate thickness was 2.1 mm and dog-bone tensile specimens were extracted using a CNC router. Some of the specimens were impacted at low velocities from two different heights to study the change in thermo-mechanical response, post-impact, during tensile test. Temperature response as a function of applied stress, failure strain and work done suggests that there is a correlation between the fracture events that take place during tensile test with the temperature response. In cases where there was a plydrop failure, the rate of temperature change could identify the failure events, even though the resultant peak temperature was less. When the specimen failed by a single mode of failure (delamination/ fiber failure), the temperature rise was found to be proportional to the input work done during tensile testing. Copyright © 2017 ASME.
About the journal
JournalASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)
PublisherAmerican Society of Mechanical Engineers (ASME)
Open AccessNo
Concepts (35)
  •  related image
    Carbon fibers
  •  related image
    Characterization
  •  related image
    Damage detection
  •  related image
    Fiber reinforced plastics
  •  related image
    Fibers
  •  related image
    FLAX
  •  related image
    Fracture
  •  related image
    Glass
  •  related image
    Glass fibers
  •  related image
    HEMP
  •  related image
    KENAF FIBERS
  •  related image
    Laminated composites
  •  related image
    Laminates
  •  related image
    LINEN
  •  related image
    Mechanisms
  •  related image
    NATURAL FIBERS
  •  related image
    POLYESTER RESINS
  •  related image
    Polymers
  •  related image
    Risk analysis
  •  related image
    Risk assessment
  •  related image
    Safety engineering
  •  related image
    Synthetic fibers
  •  related image
    Tensile testing
  •  related image
    Textile finishing
  •  related image
    Weaving
  •  related image
    Yarn
  •  related image
    Critical applications
  •  related image
    Fiber reinforced polymers
  •  related image
    Hybrid composite laminate
  •  related image
    HYBRID POLYMER COMPOSITE
  •  related image
    INFRARED THERMOGRAPHS
  •  related image
    NATURAL FIBER COMPOSITES
  •  related image
    STIFFNESS CHARACTERISTICS
  •  related image
    THERMO-MECHANICAL RESPONSE
  •  related image
    Fiber reinforced materials