Study of ultrasound stiffness imaging methods using tissue mimicking phantoms
Suresh Krishnamoorthy Seshadri,
Published in Elsevier B.V.
2014
PMID: 24083832
Volume: 54
   
Issue: 2
Pages: 621 - 631
Abstract
A pilot study was carried out to investigate the performance of ultrasound stiffness imaging methods namely Ultrasound Elastography Imaging (UEI) and Acoustic Radiation Force Impulse (ARFI) Imaging. Specifically their potential for characterizing different classes of solid mass lesions was analyzed using agar based tissue mimicking phantoms. Composite tissue mimicking phantom was prepared with embedded inclusions of varying stiffness from 50 kPa to 450 kPa to represent different stages of cancer. Acoustic properties such as sound speed, attenuation coefficient and acoustic impedance were characterized by pulse echo ultrasound test at 5 MHz frequency and they are ranged from (1564 ± 88 to 1671 ± 124 m/s), (0.6915 ± 0.123 to 0.8268 ± 0.755 db cm-1 MHz-1) and (1.61×106 ± 0.127 to 1.76 × 106 ± 0.045 kg m-2 s-1) respectively. The elastic property Young's Modulus of the prepared samples was measured by conducting quasi static uni axial compression test under a strain rate of 0.5 mm/min upto 10 % strain, and the values are from 50 kPa to 450 kPa for a variation of agar concentration from 1.7% to 6.6% by weight. The composite phantoms were imaged by Siemens Acuson S2000 (Siemens, Erlangen, Germany) machine using linear array transducer 9L4 at 8 MHz frequency; strain and displacement images were collected by UEI and ARFI. Shear wave velocity 4.43 ± 0.35 m/s was also measured for high modulus contrast (18 dB) inclusion and X.XX m/s was found for all other inclusions. The images were pre processed and parameters such as Contrast Transfer Efficiency and lateral image profile were computed and reported. The results indicate that both ARFI and UEI represent the abnormalities better than conventional US B mode imaging whereas UEI enhances the underlying modulus contrast into improved strain contrast. The results are corroborated with literature and also with clinical patient images. © 2013 Elsevier B.V. All rights reserved.
About the journal
JournalData powered by TypesetUltrasonics
PublisherData powered by TypesetElsevier B.V.
ISSN0041624X
Open AccessNo
Concepts (59)
  •  related image
    Acoustic impedance
  •  related image
    Acoustic properties
  •  related image
    Algae
  •  related image
    Compression testing
  •  related image
    Elastic moduli
  •  related image
    Medical imaging
  •  related image
    Polysaccharides
  •  related image
    Shear flow
  •  related image
    Shear waves
  •  related image
    Stiffness
  •  related image
    Strain rate
  •  related image
    Tissue engineering
  •  related image
    Ultrasonics
  •  related image
    Wave propagation
  •  related image
    ACOUSTIC CHARACTERIZATION
  •  related image
    ACOUSTIC RADIATION FORCE IMPULSE IMAGING
  •  related image
    CONTRAST-TRANSFER EFFICIENCY
  •  related image
    ELASTIC CHARACTERIZATION
  •  related image
    ELASTOGRAPHY
  •  related image
    LINEAR ARRAY TRANSDUCERS
  •  related image
    TISSUE MIMICKING PHANTOM
  •  related image
    UNI-AXIAL COMPRESSION TESTS
  •  related image
    Tissue
  •  related image
    Animal
  •  related image
    Biomimetics
  •  related image
    Device failure analysis
  •  related image
    Devices
  •  related image
    Echography
  •  related image
    ELASTOGRAPHY
  •  related image
    Equipment design
  •  related image
    Human
  •  related image
    Image quality
  •  related image
    Neoplasm
  •  related image
    Procedures
  •  related image
    Reproducibility
  •  related image
    Sensitivity and specificity
  •  related image
    ACOUSTIC CHARACTERIZATION
  •  related image
    Article
  •  related image
    ELASTIC CHARACTERIZATION
  •  related image
    ELASTOGRAPHY
  •  related image
    Equipment
  •  related image
    EQUIPMENT FAILURE
  •  related image
    Methodology
  •  related image
    TISSUE MIMICKING PHANTOM
  •  related image
    ULTRASOUND STIFFNESS IMAGING
  •  related image
    Animals
  •  related image
    ELASTICITY IMAGING TECHNIQUES
  •  related image
    Equipment failure analysis
  •  related image
    Humans
  •  related image
    Neoplasms
  •  related image
    PHANTOMS, IMAGING
  •  related image
    Reproducibility of results
  •  related image
    ACOUSTIC CHARACTERIZATION
  •  related image
    ELASTIC CHARACTERIZATION
  •  related image
    ELASTOGRAPHY
  •  related image
    TISSUE MIMICKING PHANTOM
  •  related image
    ULTRASOUND STIFFNESS IMAGING
  •  related image
    ELASTICITY IMAGING TECHNIQUES
  •  related image
    PHANTOMS, IMAGING