Seismic retrofit of columns in buildings for flexure using concrete jacket
Published in
2009
Volume: 46
   
Issue: 2
Pages: 77 - 107
Abstract
To prevent disaster in future earthquakes, the existing deficient buildings need to be retrofitted. One way of retrofitting the columns in reinforced concrete multistoreyed buildings is concrete jacketing. The present study has investigated the effect of jacketing on the flexural strength and performance of columns. First, slant shear tests were conducted to study the interface between the old and new concrete. Second, column specimens were tested to study the strength. Third, beam-column-joint sub-assemblage specimens were tested to study the ductility (or energy absorption) and energy dissipation. Analytical investigations were carried out to predict the experimental results. A lamellar approach and a simplified method of analysis were used for the prediction of the axial load versus moment interaction curves and moment versus curvature curves for the retrofitted columns. An incremental nonlinear analysis was adopted to predict the lateral load versus displacement behaviour for a retrofitted sub-assemblage specimen. Guidelines for the retrofitting of columns by concrete jacketing are provided.
About the journal
JournalISET Journal of Earthquake Technology
ISSN09720405
Open AccessNo
Concepts (11)
  •  related image
    BEAM-COLUMNS
  •  related image
    COLUMN
  •  related image
    CONCRETE JACKETING
  •  related image
    LAMELLAR ANALYSIS
  •  related image
    Retrofit
  •  related image
    Disaster prevention
  •  related image
    Energy dissipation
  •  related image
    Forecasting
  •  related image
    Nonlinear analysis
  •  related image
    Reinforced concrete
  •  related image
    Retrofitting