Parametric analysis on the thermal comfort of a cooling tower based thermally activated building system in tropical climate – An experimental study
Published in Elsevier Ltd
2018
Volume: 138
   
Pages: 325 - 335
Abstract
Thermally Activated Building System (TABS) provides not only better thermal comfort but also good indoor air quality. It can be coupled with passive cooling systems as it can operate at a relatively higher water temperature. Even though TABS is a promising energy-efficient and eco-friendly system, the influences of various design and operating parameters on the indoor thermal comfort of a building with TABS are not well understood. Hence, the influences of cooling surfaces (area), shading, natural ventilation and ceiling fan on the performance of cooling tower based TABS were investigated in an experimental room of dimensions 3.5 m × 3.5 m × 3.15 m. The increase in the number of cooling surfaces decreased (favourable) the thermal comfort indices and advanced the time at which their maximum and minimum were reached. The average predicted percentage of dissatisfied was 89% if roof alone was cooling. This reduced to 20% if all the surfaces of the building were cooled. Shading of the roof reduced the maximum operating temperature of the indoor space by 0.9 °C when all the surfaces of the building were cooled with TABS. The use of ceiling fan increased the indoor operative temperature marginally. However, the increase was less than the neutral temperature offset of 2.6 °C that was achieved by higher air movement. Thus, the use of the fan results in a better indoor thermal comfort. Natural ventilation advanced the occurrence of the maximum temperature of indoor air by 1½ and 2¾ hours for fan off and fan on cases respectively. It also advanced the extrema of the other indoor comfort parameters. The cooling tower based TABS was able to achieve thermal comfort even in unfavourable warm and humid tropical climates under certain operating conditions. © 2018 Elsevier Ltd
About the journal
JournalData powered by TypesetApplied Thermal Engineering
PublisherData powered by TypesetElsevier Ltd
ISSN13594311
Open AccessNo
Concepts (19)
  •  related image
    Air conditioning
  •  related image
    Air quality
  •  related image
    Buildings
  •  related image
    COOLING TOWERS
  •  related image
    Energy efficiency
  •  related image
    Indoor air pollution
  •  related image
    ROOFS
  •  related image
    Temperature
  •  related image
    Thermal comfort
  •  related image
    Ventilation
  •  related image
    HUMID TROPICAL CLIMATES
  •  related image
    INDOOR THERMAL COMFORT
  •  related image
    Operating temperature
  •  related image
    Operative temperature
  •  related image
    Parametric -analysis
  •  related image
    PASSIVE COOLING
  •  related image
    THERMAL COMFORT INDEX
  •  related image
    THERMALLY ACTIVATED
  •  related image
    Cooling systems