On the suitability of broadband attenuation measurement for characterizing contrast microbubbles
Published in
2005
PMID: 15936494
Volume: 31
   
Issue: 6
Pages: 781 - 786
Abstract
Broadband attenuation measurement has been widely used for characterizing ultrasound contrast agents. Chen et al. (2002) recently suggested that broadband attenuation data depend on the center frequency of the broadband excitation pulse and, therefore, that they are not a reliable measure of the bubble behavior. We investigated the suitability of measurement of broadband attenuation as a characterizing tool using the contrast agent Definity® as a test case. Analyzing the attenuation data obtained with three broadband unfocused transducers with different center frequencies (2.25, 3.5 and 5 MHz), we found that attenuation is independent of the transducer used and matches in the overlap regions of any two transducers. Attenuation does not depend on excitation pressure amplitude as long as the excitation amplitude remains below a critical value (≈ 0.26 MPa), indicating that the measurement of broadband attenuation below critical excitation can, indeed, be used for characterization. Furthermore, the linear relationship of attenuation with concentrations of Definity® is also investigated. © 2005 World Federation for Ultrasound in Medicine & Biology.
About the journal
JournalUltrasound in Medicine and Biology
ISSN03015629
Open AccessNo
Concepts (25)
  •  related image
    Linear systems
  •  related image
    Transducers
  •  related image
    Ultrasonics
  •  related image
    BROADBAND ATTENUATION
  •  related image
    Broadband excitation
  •  related image
    PRESSURE AMPLITUDE
  •  related image
    Attenuation
  •  related image
    Contrast medium
  •  related image
    PERFLUTREN
  •  related image
    Article
  •  related image
    Data analysis
  •  related image
    Linear system
  •  related image
    Microbubble
  •  related image
    Priority journal
  •  related image
    Reliability
  •  related image
    SIGNAL AVERAGED ELECTROCARDIOGRAPHY
  •  related image
    ULTRASOUND TRANSDUCER
  •  related image
    Contrast media
  •  related image
    Fluorocarbons
  •  related image
    Humans
  •  related image
    Microbubbles
  •  related image
    Scattering, radiation
  •  related image
    Sensitivity and specificity
  •  related image
    Signal processing, computer-assisted
  •  related image
    ULTRASONOGRAPHY, INTERVENTIONAL