Header menu link for other important links
X
Microwave based conductivity monitoring of glass melts used for nuclear waste management
Published in Institute of Electrical and Electronics Engineers
2019
Pages: 506 - 508
Abstract
A non-contact microwave measurement technique to measure the change in conductivity profile of glass mixture with temperature (30-700°C is presented here. Mono static radio detection and ranging (RADAR) signals from the glass melts recorded using a corrugated horn are processed to identify the relative change in material conductivity with respect to temperature. © 2019 IEEE.