Header menu link for other important links
X
Experimental validation of an eddy current probe for defect detection in thick conducting specimen
P. Mahesh Raja, , Krishnan Balasubramanian
Published in American Institute of Physics Inc.
2016
Volume: 1706
   
Abstract
This paper presents numerical modeling and experimental measurements of eddy current (EC) probe for detecting subsurface defects in 10 mm to 15 mm thick conducting specimen. Measurements are presented for a pancake air core coil to detect subsurface defect in 10 mm thick aluminum slab. EC coil parameters namely inner radius(r1), and outer radius(r2), and operating frequency (f) are optimized for deeper penetration in the conducting plate (35 MS/m) for a given coil height(h), and lift off distance (d). Preliminary simulation results are presented for a subsurface defect in 15 mm thick aluminium plate for the optimized EC coil parameters. © 2016 AIP Publishing LLC.
About the journal
JournalData powered by TypesetAIP Conference Proceedings
PublisherData powered by TypesetAmerican Institute of Physics Inc.
ISSN0094243X
Open AccessYes