Effect of component pressure drops in two-fluid pumpless continuous vapour absorption refrigerator
Published in Elsevier Ltd
1997
Volume: 38
   
Issue: 18
Pages: 1823 - 1832
Abstract
Miniaturisation of the vapour absorption refrigerator requires replacement of the solution pump by a heat operated bubble pump and air cooled condenser and absorber. The replacement necessitates the selection of working media restricted to vacuum operation, and the air cooling poses the problem of high pressure drops in the refrigerator. Thermodynamic analysis of the absorption refrigerator with such a suitable working medium is performed considering the pressure drops in the system as parameters. The analysis shows that the effect of the evaporator to absorber pressure drop on the system performance is more significant than that of the generator to condenser pressure drop, and it becomes more predominant at the low generator temperature normally encountered in solar operated systems. © 1997 Elsevier Science Ltd.