Header menu link for other important links
X
Decay heat removal in pool type fast reactor using passive systems
, , Perumal Chellapandi
Published in
2012
Volume: 250
   
Pages: 480 - 499
Abstract
Post shutdown decay heat removal in a fast reactor is one of the most important safety functions which must be accomplished with a very high reliability. To achieve high reliability, the fast breeder reactor design has emphasized on passive or near passive decay heat removal systems utilizing the natural convection in the heat removal path. A typical passive decay heat removal system used in recent designs of fast breeder reactors consists of a sodium to sodium heat exchanger and sodium to air heat exchanger which together remove heat directly from the hot pool to the final heat sink, which is air. Since these are safety systems, it is necessary to confirm the design with detailed numerical analysis. The numerical studies include pool hydraulics, natural convection phenomena in closed loops, flow through narrow gaps between SA, multi-scale modeling, etc. Toward understanding the evolution of thermal hydraulic parameters during natural convection decay heat removal, a three-dimensional CFD model for the primary system coupled with an appropriate one-dimensional model for the secondary system is proposed. The model has been validated against the results of natural convection test conducted in PHENIX reactor. Adopting the model for the Indian PFBR, six different decay heat removal cases have been studied which bring out the effect of safety grade decay heat removal system (SGDHRS) capacity, secondary sodium inventory and inter-wrapper flow heat transfer on the subassembly outlet temperatures that are important for safety evaluation of the reactor. From the results, it is concluded that the delay in initiation of SGDHRS, replacement of intermediate sodium in SGDHRS with NaK and a decrease in the AHX air inlet temperature do not change the temperatures of the primary circuit significantly. The secondary sodium inventory plays an important role in reducing the temperatures in the primary coolant. The beneficial effect of inter-wrapper flow heat transfer on primary temperatures is limited to about 20 K in the fissile zone and 50 K in the blanket zone. These results are very important and give direction for future designs of fast breeder reactors. © 2012 Elsevier B.V.
About the journal
JournalNuclear Engineering and Design
ISSN00295493
Open AccessNo
Concepts (36)
  •  related image
    AIR INLET TEMPERATURE
  •  related image
    Beneficial effects
  •  related image
    Closed loops
  •  related image
    Convection phenomena
  •  related image
    Decay heat removal
  •  related image
    DECAY HEAT REMOVAL SYSTEMS
  •  related image
    FAST BREEDER REACTORS
  •  related image
    Flowthrough
  •  related image
    FUTURE DESIGNS
  •  related image
    Heat removal
  •  related image
    High reliability
  •  related image
    MULTI-SCALE MODELING
  •  related image
    NARROW GAP
  •  related image
    Numerical studies
  •  related image
    One-dimensional model
  •  related image
    Outlet temperature
  •  related image
    Passive decay
  •  related image
    Passive systems
  •  related image
    PRIMARY CIRCUITS
  •  related image
    PRIMARY COOLANTS
  •  related image
    Primary systems
  •  related image
    Safety evaluations
  •  related image
    SAFETY FUNCTIONS
  •  related image
    SAFETY GRADE
  •  related image
    SECONDARY SYSTEM
  •  related image
    THERMAL HYDRAULIC PARAMETERS
  •  related image
    THREE-DIMENSIONAL CFD MODEL
  •  related image
    Breeder reactors
  •  related image
    Computational fluid dynamics
  •  related image
    Design
  •  related image
    Fast reactors
  •  related image
    Heat exchangers
  •  related image
    Lakes
  •  related image
    Natural convection
  •  related image
    Sodium
  •  related image
    Decay (organic)