Header menu link for other important links
X
Consistent malfunction diagnosis inside control loops using signed directed graphs
Maurya M.R., , Venkatasubramanian V.
Published in Elsevier
2003
Volume: 14
   
Pages: 473 - 478
Abstract
Though signed directed graphs (SDG) have been widely used for modeling control loops, due to lack of adequate understanding of SDG-based steady state process modeling, special and cumbersome methods are used to analyze control loops. In this article, we discuss a unified SDG model for control loops (proposed by Maurya et al. (2002b)), in which both disturbances (sensor bias etc.) as well as structural faults (sensor failure etc.) can be easily modeled. Various fault scenarios such as external disturbances, sensor bias, controller failure etc. have been discussed. Two case studies are presented to show the utility of the SDG model for fault diagnosis. A tank-level control system is used as first case study. The second case study deals with fault diagnosis of a multi-stream controlled CSTR. © 2003 Elsevier B.V. All rights reserved.
About the journal
JournalData powered by TypesetComputer Aided Chemical Engineering
PublisherData powered by TypesetElsevier
ISSN15707946
Open AccessNo