Assessment of sensitization in aisi 304 stainless steel by nonlinear ultrasonic method
Published in
2013
Volume: 26
   
Issue: 5
Pages: 545 - 552
Abstract
A nonlinear ultrasonic technique has been developed to evaluate sensitization in Type 304 stainless steel. In order to achieve different degree of sensitization (DOS), specimens have been subjected to heat treatment at 675 °C at varying soaking time (0.5, 1.0, 2.0, 3.0 and 4.0 h). Heat treated specimens were subjected to intergranular corrosion tests as per ASTM standards A262 and G108. Sensitization in longer soaked material has been confirmed through ditch microstructures, cracks on the bend tested specimens and higher degree of sensitization. Nonlinear ultrasonic studies showed variation in the nonlinearity parameter with soaking time which also confirms sensitization. A good correlation was observed between the degree of sensitization measured by the electrochemical potentiokinetic reactivation test and the ultrasonic nonlinearity parameter. This study clearly demonstrated that nonlinear ultrasonic technique can be used as a potential technique for non-destructive characterization of sensitization in austenitic stainless steel. © The Chinese Society for Metals and Springer-Verlag Berlin Heidelberg.
About the journal
JournalActa Metallurgica Sinica (English Letters)
ISSN10067191
Open AccessYes
Concepts (12)
  •  related image
    DEGREE OF SENSITIZATION
  •  related image
    DEGREE OF SENSITIZATIONS (DOS)
  •  related image
    ELECTROCHEMICAL POTENTIOKINETIC REACTIVATION TESTS
  •  related image
    Intergranular corrosion
  •  related image
    NON-LINEAR ULTRASONICS
  •  related image
    Nondestructive characterization
  •  related image
    Type 304 stainless steel
  •  related image
    ULTRASONIC NONLINEARITIES
  •  related image
    Austenitic stainless steel
  •  related image
    Nondestructive examination
  •  related image
    Textures
  •  related image
    Ultrasonic testing