A virtual instrument for automated measurement of arterial compliance
V. Jayashankar,
Published in
2010
Volume: 4
   
Issue: 4
Abstract
Measurement of arterial distensibility is very important in cardiovascular diagnosis for early detection of coronary heart disease and possible prediction of future cardiac events. Conventionally, B-mode ultrasound imaging systems have been used along with expensive vessel wall tracking systems for estimation of arterial distension and calculation of various estimates of compliance. We present a simple instrument for noninvasive in vivo evaluation of arterial compliance using a single element ultrasound transducer. The measurement methodology is initially validated using a proof of concept pilot experiment using a commercial ultrasound pulser-receiver. A prototype system is then developed around a PXI chassis using LABVIEW software. The virtual instrument employs a dynamic threshold algorithm to identify the artery walls and then utilizes a correlation based tracking technique to estimate arterial distension. The end-diastolic echo signals are averaged to reduce error in the automated diameter measurement process. The instrument allows automated measurement of the various measures of arterial compliance with minimal operator intervention. The performance of the virtual instrument was first analyzed using simulated data sets to establish the maximum measurement accuracy achievable under different input signal to noise ratio (SNR) levels. The system could measure distension with accuracy better than 10 μm for positive SNR. The measurement error in diameter was less than 1%. The system was then thoroughly evaluated by the experiments conducted on phantom models of the carotid artery and the accuracy and resolution were found to meet the requirements of the application. Measurements performed on human volunteers indicate that the instrument can measure arterial distension with a precision better than 5%. The end-diastolic arterial diameter can be measured with a precision better than 2% and an accuracy of 1%. The measurement system could lead to the development of small, portable, and inexpensive equipment for estimation of arterial compliance suitable in mass screening of "at risk" patients. The automated compliance measurement algorithm implemented in the instrument requires minimal operator input. The instrument could pave the way for dedicated systems for arterial compliance evaluation targeted at the general medical practitioner who has little or no expertise in vascular ultrasonography. © 2010 American Society of Mechanical Engineers.
About the journal
JournalJournal of Medical Devices, Transactions of the ASME
ISSN19326181
Open AccessNo
Concepts (44)
  •  related image
    Biomedical instrumentation
  •  related image
    CAROTID ARTERY
  •  related image
    NONINVASIVE DIAGNOSIS
  •  related image
    NONINVASIVE MEASUREMENTS
  •  related image
    Ultrasound
  •  related image
    VIRTUAL INSTRUMENT
  •  related image
    Algorithms
  •  related image
    Automation
  •  related image
    Computer programming languages
  •  related image
    Diagnosis
  •  related image
    DIGITAL INSTRUMENTS
  •  related image
    Economic analysis
  •  related image
    Estimation
  •  related image
    Mathematical operators
  •  related image
    Risk perception
  •  related image
    Signal to noise ratio
  •  related image
    Ultrasonic imaging
  •  related image
    Ultrasonic transducers
  •  related image
    Ultrasonics
  •  related image
    Ultrasonography
  •  related image
    Measurements
  •  related image
    Accuracy
  •  related image
    ARTERIAL WALL THICKNESS
  •  related image
    ARTERY COMPLIANCE
  •  related image
    ARTERY DIAMETER
  •  related image
    Article
  •  related image
    CARDIOVASCULAR EQUIPMENT
  •  related image
    CAROTID ARTERY
  •  related image
    Computer program
  •  related image
    Controlled study
  •  related image
    Correlation analysis
  •  related image
    Echocardiography
  •  related image
    Human
  •  related image
    Human cell
  •  related image
    In vivo study
  •  related image
    Ischemic heart disease
  •  related image
    Mass screening
  •  related image
    Measurement error
  •  related image
    MODELS AND PHANTOMS
  •  related image
    NON INVASIVE PROCEDURE
  •  related image
    Risk
  •  related image
    SIGNAL NOISE RATIO
  •  related image
    Simulation
  •  related image
    ULTRASOUND TRANSDUCER