Header menu link for other important links
X
A comparison between finite element modeling and various thermographic non-destructive testing techniques for the quantification of the thermal integrity of macro-brush plasma facing components used in a tokamak
Published in American Institute of Physics Inc.
2016
Volume: 87
   
Issue: 2
Abstract
The plasma facing components (PFCs) inside a tokamak are typically exposed to extremely high heat flux of the order of MW/m2. The brazing quality between the plasma facing materials (PFMs) and the heat sink will determine the structural integrity and hence the effective service life of these PFCs. Suitable non-destructive testing (NDT) techniques for the pre-qualification of these components are thus essential to evaluate their structural integrity at various stages of their service life. Macro-brush type mockups of prototype PFCs with graphite as PFM have been inspected for their brazing quality using different active Infrared (IR)-thermographic NDT techniques. The results obtained from these techniques are compared and discussed. The brazing quality was quantified by establishing a comparison between the experimental results and the results from Finite Element Analysis (FEA). The percentage of contact between the PFM and the substrate was varied in FEA. FEA results when compared with experiments shows that tiles have different amounts of contact with the substrate ranging between 10% and 80%. © 2016 AIP Publishing LLC.
About the journal
JournalData powered by TypesetReview of Scientific Instruments
PublisherData powered by TypesetAmerican Institute of Physics Inc.
ISSN00346748
Open AccessNo
Concepts (16)
  •  related image
    Brazing
  •  related image
    Bridge decks
  •  related image
    Finite element method
  •  related image
    Heat flux
  •  related image
    Magnetoplasma
  •  related image
    Quality control
  •  related image
    Structural integrity
  •  related image
    Testing
  •  related image
    Tokamak devices
  •  related image
    Exposed to
  •  related image
    High heat flux
  •  related image
    Non destructive testing
  •  related image
    PLASMA FACING MATERIALS
  •  related image
    PLASMA-FACING COMPONENTS
  •  related image
    PRE-QUALIFICATION
  •  related image
    Nondestructive examination